ExiPrep™ Nucleic Acids Sample Preparation System
Product Features
ExiPrep™ is a instrument that automatically extracts nucleic acids from up to 16/48/96 samples.
Intro Video for ExiPrep™96 Lite: https://youtu.be/17V2SM-MNRI
Brand: Bioneer
Cat. No.: (16) A-5030, (48) A-5150-1, (96) A-5250(RUO)
Product Features:
A-5030 - ExiPrep™ 16
ExiPrep™ 16 Plus extracts nucleic acids and purifies protein automatically up to 16 samples. Through optimized experimental protocols, it not only allows to get reproducible results, but also wide compatibility with various types of nucleic acids and protein samples. Furthermore, this instrument has excellent space utilization thanks to its small size.
- Built-in optimized nucleic acid extraction protocol
Simplified usage and reproducible results with built-in nucleic acid extraction and protein purification protocols optimized for various samples and targets - High-purity nucleic acid extraction
Extraction of highly pure nucleic acids by attaching magnetic particles to the bottom of each well equally and rapidly by magnetic blocks attached to the instrumentIncreased elution efficiency allowing complete evaporation of alcohols by its heating block
- Prevention of contamination
Substantial blocking of cross-contamination, which may occur in other wells by the aerosols generated from the tip, through the sophisticated designs drop-contamination prevention device located at the bottom of the filter tip - Automatic UV sterilization
Sterilization to prevent infection for the users by the samples through the UV lamp installed inside the instrument - Easy-to-use
User-friendly UI capable of checking the experimental progress rate real-time without the need of seperate PC by equipping with a 3.5-inch touch screen on the front of the device - Excellent Precision
Minimized error range, that may occur during the automatic dispensing of the solution, through installment of an adjustable syringe motor up to 0.1 mm capable of stably distributing in a volume of 25 ㎕ ~ 1000 ㎕ for application to various protocols and obtaining of experimental results
A-5150-1 - ExiPrep™ 48
ExiPrep™ 48 is a instrument that automatically extracts nucleic acids from at least 8 to 48 samples and evenly dispenses them while preventing cross-contamination of aerosols. It is best optimized for screening of high-sensitivity virus.
- High-sensitivity virus screening optimization
No false positives by preventing cross-contamination of virus-free samples, caused by micro-aerosols when extracting nucleic acids from samples containing high concentration of viruses through Bioneer's patent technology - Prevention of contamination
Substantial blocking of cross-contamination, which may occur in other wells by the aerosols generated from the tip, through the sophisticated designs of aerosol prevention device by the closed structure of pipette block and the drop-contamination prevention device at the bottom of the filter tip - High purity nucleic acid extraction
Extraction of highly pure nucleic acids by attaching magnetic particles to the bottom of each well equally and rapidly by magnetic blocks attached to the instrumentIncreased elution efficiency allowing complete evaporation of alcohols by its heating block
- Automatic UV sterilization
Sterilization to prevent infection for the users by the samples through the UV lamp installed inside the instrument - Minimized reagent waste
Reduced waste of reagents and quick processing through extraction of nucleic acids from 8 to 48 samples simultaneously in 8 units at the time of its operation - Convenience
User-friendly UI without the need of seperate PC by equipping with a 13.3-inch touch screen on the front of the instrument - Built-in optimized nucleic acid extraction protocol
Easy to use and reproducible results with built-in nucleic acid extraction protocols optimized for various samples and targets - Automatic punching function
Radical elimination of aerosol contamination chance by automatic punching in the instrument
A-5250(RUO) - ExiPrep™ 96
ExiPrep™96 Lite is a instrument that automatically extracts nucleic acids using magnetic rods from up to 96 samples. Nucleic acid extraction is possible within less than 30 minutes in a small place (width 40 x height 58 cm).
- Simultaneous sample extraction
Nucleic acid extraction from at least 32 to 96 samples by magnetic rods composed of 32 units, allowing usage without reagent waste - Built-in optimized nucleic acid extraction protocol
Built-in optimized nucleic acid extraction protocol for optimized kits and various samples, with a function for users to easily create their own protocol for special samples - Minimize nucleic acid extraction time
Quick nucleic acid extraction time only within 30 minutes - Wide compatibility
Nucleic acid extraction possible from various types of sample such as blood, bacteria, tissues, cells, plants, etc. - Prevention of contamination
Various parts such as UV lamp, contamination shield, etc. equipped to prevent contamination - Minimum workspace
Minimized equipment size and increased lab space efficiency