top of page
  • Facebook
  • Instagram
  • Linkedin
  • Labware e-shop
Jeio Tech Pharmaceutical Stability Test Chamber (TH4-ICH)

Jeio Tech Pharmaceutical Stability Test Chamber (TH4-ICH)

SKU: TH4-ICH

In order to conduct ICH Q1A (R2) and ICH Q1B tests

 

Product Advantages

Stability Test (ICH Guideline Q1A (R2))

  • Supports long-term stability testing with an energy-saving inverter refrigeration system and PID control, ensuring stable temperature and humidity while reducing energy consumption.
  • Maintains the same temperature and humidity control range regardless of lamp On/Off status.
  • Enables continuous operation without defrosting, even during 5°C long-term stability testing.
  • Optional recorder supports test record management.
  • Inner glass door allows internal observation and sample access during testing.

 

Photostability Testing(ICH Q1B Option 2)

  • VIS and UV-A light sources compliant with ICH guidelines can be independently controlled inside the chamber.
  • Light sensors accurately measure actual and accumulated light exposure values and display them on the controller.
  • Displays accumulated exposure time for VIS/UV-A and the remaining time to reach the target value for convenient test management.
  • Auto lamp-off function turns off the lamps when the preset target value for each light type is reached.

 

Structural Functional Features

  • Specially manufactured filters and optimized lamp arrangement deliver uniform illuminance throughout the vertical area.
  • Stable horizontal airflow ensures consistent temperature and humidity, even with large sample loads.
  • External humidification system improves stable humidity control and keeps the test space clean and easy to maintain.
  • Excellent insulation and sealing ensure stable temperature and humidity reproducibility during repeated long-term testing.
  • Space-saving slim design.
  • Double-sealed door structure provides enhanced airtightness.

 

Multi-Function Control and Communication System

  • Supports both fixed control and program control.
  • Allows various test conditions with 10 programs, 10 steps, and up to 99 repeat cycles.
  • Saves program information and backs up set values.
  • Temperature/humidity auto-tuning and temperature calibration support reliable control.
  • Calibration functions are available for temperature, humidity, VIS, and UV-A.
  • PID control divided into 16 zones enables more precise and stable control.
  • Data can be stored in internal memory and USB external memory.
  • RS-232 port is included as standard, and RS-485 port is available as an option.
  • Dedicated PC monitoring software is included as standard for equipment control, data monitoring, and data storage(Up to 4 units can be connected)
  • LC Connected mobile monitoring system enables monitoring anytime, anywhere via a mobile app when connected with LC GreenBox. (LC GreenBox required)
  • Supports Jeio Tech LC DataKeeper, a data integrity software in compliance with FDA 21 CFR Part 11, for GMP audit readiness.(Option)

 

Please visit the Jeio Tech website for more information

Brand: Jeio Tech
Model: TH4-ICH-400/400A

 

Model TH4-ICH-400 TH4-ICH-400A
Interior dimensions    
Chamber volume (L / cu ft) 400 / 14.13 400 / 14.13
Width (mm / inch) 595 / 23.43 595 / 23.43
Depth (mm / inch) 710 / 27.95 710 / 27.95
Height (mm / inch) 960 / 37.8 960 / 37.8
Quantity of shelves (standard/max.) 2 / 2 2 / 8
Distance between lamp and shelf (mm / inch) 150 / 5.91 -
Distance between shelves (mm / inch) - 90 / 3.54
Max. load per shelf (kg / lbs) 20 / 44.1 20 / 44.1
Permitted total load (kg / lbs) 65 / 143.3 65 / 143.3
Cable port (Ø, mm / inch) 50 / 1.97 50 / 1.97
Water tank capacity (L / cu ft) 12 / 0.42 12 / 0.42
Weight (kg / lbs) 270 / 595.25 270 / 595.25
Temperature data    
Range without humidity (without light) 0 to 70 0 to 70
Range without humidity (with light) 5 to 70 -
Fluctuation (±°C / °F) ±0.5 / ±0.9 ±0.5 / ±0.9
Gradient (°C / °F)1) <3.0 / <5.4 <3.0 / <3.6
Humidity data    
Range (%RH) 20 to 75 20 to 75
Fluctuation (±%RH) 2 2
Recovery time 25°C/60% (30s door open) (min) 4 4
Light data (ICH Q1B option 2)    
Cool white at 25°C (Lux) 12000 -
Ultraviolet-A at 25°C (W/m²) 8 -
Uniformity of Visible light (±%) 10 -
Uniformity of Ultraviolet-A light (±%) 10 -
Typical time 1.2 million Lux·hr (hr) 100 -
Typical time 200 W·hr/m² (hr) 25 -
Electrical data & Ordering information    
Plug type2) Industrial (3pin) Industrial (3pin)
Power consumption (A) 20 18

※ Above specifications are based on DIN 12880 and IEC 60068 standards.
※ Ambient conditions of the device shall be within 18–30°C (Recommended: 20°C), 85%RH or less, and 2000m or less above sea level.
※ DI water specification is pH 6.2–7.2 and electrical conductivity ≤ 20 μS/cm.
1) Gradient is the maximum temperature deviation between the highest and lowest values among the 9 temperature sensors.
2) Check the plug type and the electrical capacity of the installation site.

 

Get a Price Quote

Thanks! We will send you a quotation as soon as possible.

bottom of page